17-10206 Display Image

Lenticium GFP - Tubulin Lentiviral

Code: 17-10206 D2-231

Non disponible en dehors du Royaume-Uni et de l'Irlande

Application

Research Sub CategoryCytoskeleton

Research CategoryCell Structure

Fluorescence microscopy imaging:
HT-1080 cells were plated in ...


en savoir plus

Votre prix
$624.95 EACH
$749.94 inc. VAT

Non disponible en dehors du Royaume-Uni et de l'Irlande

Application

Research Sub CategoryCytoskeleton

Research CategoryCell Structure

Fluorescence microscopy imaging:
HT-1080 cells were plated in a chamber slide and transduced with lentiviral particles at an MOI of 20 for 24 hours. After media replacement and 48 hours further incubation, cells were fixed with formaldehyde and mounted. Image was obtained by oil immersion wide-field fluorescence microscopy. The GFP-tubulin displays predominantly cytoplasmic, fibrillar signal. Able to visualize mitotic cells with visible spindle apparatus formation.

Immunocytochemistry Comparison and Modulator Analysis:
(See Figure 2 in datasheet)
Similar to Figure 1, HT-1080 cells were plated in a chamber slide and transduced with lentiviral particles at an MOI of 20 for 24 hours. After media replacement and 48 hours further incubation, cells were either left untreated, incubated for 4 hours with 1 µM paclitaxel (PTX, a microtubule stabilizer), or incubated for 4 hours with 25 µM nocodazole (NZL, a microtubule depolymerization agent). PTX-treated cells become rounded and display the formation of tubulin “bundles”, while NZL eliminates fibrillar tubulin structure. Immunocytochemical staining (red) of the same fields of view with a monoclonal antibody against α-tubulin reveals similar expression patterns to the GFP-protein (green).

Hard-to-transfect Cell Types:
(See Figure 3 in datasheet)
Primary cell types HUVEC or HuMSC were plated in chamber slides and transduced with lentiviral particles at an MOI of 40 for 24 hours. Cells were either left untreated, or treated for 4 hours with the microtubule stabilizer paclitaxel, at 1 µM concentration.

For optimal fluorescent visualization, it is recommended to analyze the target expression level within 24-48 hrs after transfection/infection for optimal live cell analysis, as fluorescent intensity may dim over time, especially in difficult-to-transfect cell lines. Infected cells may be frozen down after successful transfection/infection and thawed in culture to retain positive fluorescent expression beyond 24-48 hrs. Length and intensity of fluorescent expression varies between cell lines. Higher MOIs may be required for difficult-to-transfect cell lines.

Components

TagGFP2-Tubulin Lentivirus:
One vial containing 25 µL of lentiviral particles at a minimum of 3 x 10E8 infectious units (IFU) per mL.
For lot-specific titer information, please see lot specific “Viral Titer” in the product specifications of the datasheet.
Promoter
EF-1 (Elongation Factor-1)
Multiplicty of Infection (MOI)
MOI = Ratio of # of infectious lentiviral particles (IFU) to # of cells being infected.
Typical MOI values for high transduction efficiency and signal intensity are in the range of 20-40. For this target, some cell types may require lower MOIs (e.g., HT-1080, human umbilical vein endothelial cells (HUVEC)), while others may require higher MOIs (e.g., HeLa, human mesenchymal stem cells (HuMSC), U2OS).
NOTE: MOI should be titrated and optimized by the end user for each cell type and lentiviral target to achieve desired transduction efficiency and signal intensity.

General description

Read our application note in Nature Methods!http://www.nature.com/app_notes/nmeth/2012/121007/pdf/an8620.pdf(Click Here!)Learn more about the advantages of our LentiBrite Lentiviral Biosensors! Click HereBiosensors can be used to detect the presence/absence of a particular protein as well as the subcellular location of that protein within the live state of a cell. Fluorescent tags are often desired as a means to visualize the protein of interest within a cell by either fluorescent microscopy or time-lapse video capture. Visualizing live cells without disruption allows researchers to observe cellular conditions in real time.Lentiviral vector systems are a popular research tool used to introduce gene products into cells. Lentiviral transfection has advantages over non-viral methods such as chemical-based transfection including higher-efficiency transfection of dividing and non-dividing cells, long-term stable expression of the transgene, and low immunogenicity. EMD Millipore is introducing LentiBrite™ Lentiviral Biosensors, a new suite of pre-packaged lentiviral particles encoding important and foundational proteins of autophagy, apoptosis, and cell structure for visualization under different cell/disease states in live cell and in vitro analysis.•Pre-packaged, fluorescently-tagged with GFP & RFP •Higher efficiency transfection as compared to traditional chemical-based and other non-viral-based transfection methods •Ability to transfect dividing, non-dividing, and difficult-to-transfect cell types, such as primary cells or stem cells •Non-disruptive towards cellular function EMD Millipore’s LentiBrite™ GFP-A-tubulin lentiviral particles provide bright fluorescence and precise localization to enable live cell analysis of microtubule dynamics in difficult-to-transfect cell types.

Microtubules are dynamic cytoskeletal filaments composed of tubulin subunits that play central roles during mitosis (in the mitotic spindle) and during interphase as a scaffold for directed kinesin- and dynein-mediated movement of cellular cargo. Several families of microtubule-binding agents, such as taxanes and vinca alkaloids, disrupt microtubule dynamics and cause cell death, and are clinically effective chemotherapeutic agents. Imaging of microtubule dynamics in live cells expressing tubulin tagged with fluorescent proteins has contributed greatly to our understanding of microtubule-binding agents.
EMD Millipore's LentiBrite™ GFP-α-tubulin lentiviral particles provide bright fluorescence and precise localization to enable live cell analysis of microtubule dynamics in difficult-to-transfect cell types.

Legal Information

CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany

Physical form

PEG precipitation

Quality

Evaluated by transduction of HT-1080 cells and fluorescent imaging performed for assessment of transduction efficiency.

Storage and Stability

Storage and Handling
Lentivirus is stable for at least 4 months from date of receipt when stored at -80°C. After first thaw, place immediately on ice and freeze in working aliquots at -80°C. Frozen aliquots may be stored for at least 2 months. Further freeze/thaws may result in decreased virus titer and transduction efficiency.

IMPORTANT SAFETY NOTE
Replication-defective lentiviral vectors, such as the 3rd Generation vector provided in this product, are not known to cause any diseases in humans or animals. However, lentiviruses can integrate into the host cell genome and thus pose some risk of insertional mutagenesis. Material is a Risk Group 2 and should be handled under BSL2 controls. A detailed discussion of biosafety of lentiviral vectors is provided in Pauwels, K. et al. (2009). State-of-the-art lentiviral vectors for research use: Risk assessment and biosafety recommendations. Curr. Gene Ther. 9: 459-474.

detection methodfluorometric
manufacturer/tradenameLentiBrite, Chemicon®
Quality Level100
shipped indry ice
technique(s)immunocytochemistry: suitable, cell based assay: suitable, transfection: suitable, single cell analysis: suitable, immunofluorescence: suitable
UniProt accession no.P07437
Hazard Class9
Un Number3245
Ce produit répond aux critères suivants: