Conductivité de Jenway 4510

Code: con1220 D2-126

The 4510 is easy to use but with the flexibility to meet the broadest range of applications and for those where greater accuracy is required the 4510 has automatic conductivity standard recognition...


en savoir plus

Votre prix
$938.15 EACH

3 Year Warranty
Service Centre
Made In Britain
Calibration Service

The 4510 is easy to use but with the flexibility to meet the broadest range of applications and for those where greater accuracy is required the 4510 has automatic conductivity standard recognition and endpoint detection. Set-up options include cell constant, temperature coefficient and reference temperature. The instrument can store up to 32 readings, which can also be sent to a printer or transferred to computer via DataWay and the RS232 interface.

  • Simultaneous display of conductivity or TDS and temperature
  • Automatic selection of range for best resolution
  • Calibration by cell constant or standard solutions
  • Automatic standard recognition
  • Storage of up to 32 results
  • Bi-directional RS232 link to printer or PC
  • Supplied with glass conductivity probe with ATC (K=1), electrode holder, and power supply
  • 3 year warranty

45104520
Conductivity Range 6 auto-selected from 0 to 1999mS* 6 auto-selected from 0 to 19.99S*
Conductivity Resolution 0.01µS to 0.01mS 0.01µS to 0.01S
Conductivity Accuracy ±0.5% ±2 digits
Automatic std. recognition 10µS, 84µS, 1413µS, 12.88mS
Cell constant 0.010 to 19.999
TDS Range 6 auto-selected from 0-1999g/L*
TDS Resolution (accuracy) 0.01mg/L to 1g/L* (±0.5% ±2 digits)
TDS Accuracy ±0.5% ±2 digits
EC Ratio 0.50 to 0.80
Temperature Range, °C-10 to 105
Temperature Resolution, °C 0.1
Temperature Accuracy, °C±0.5
ATC and Manual, °C0 to 100
Temperature Coefficient, % /°C 0.00 to 4.00
Reference Temperature, °C 18, 20 or 25
Resistance Range, Mohm 0-20
Resistance Resolution, Mohm 0.01
Resistance Accuracy ±0.5% ±2 digits
Salinity Range, g/L 0 to 99.9
Salinity Resolution, g/L0.1
Salinity Accuracy 0-35 ±1g/L, 35-99.9 ±3g/L
Cell Constant 0.010 to 19.999
GLP Calibration reminder interval (1 to 999hrs). Alarm outputs (open collector & audible)
Outputs Analogue and RS232Analogue, RS232 and IrDA interface
Connector 7-pin DIN
Power 9V AC ±10% @ 50/60Hz
Dims, w x d x l, mm250 x 55 x 210
Weight, g850
Supplied withGlass conductivity probe with ATC (K=1) (027 013), electrode holder
Code
Description
Unité de vente
Prix annoncé
Qté
CON1230
Unité:EACH
Prix annoncé: $1,265.85
Source:Prix annoncé
Ce produit répond aux critères suivants: