Design Qualification
Regulatory bodies expect to find a DQ where the supply is bespoke.
Design Qualification
Regulatory bodies expect to find a DQ where the supply is bespoke. Constructing a useful and
meaningful DQ can be highly productive when taking on large multifaceted systems, particularly
where customisation or bespoke software is included.
Installation Qualification
The starting block for many Validation Projects.
Installation Qualification
The starting block for many Validation Projects. This is often as far as some companies get. A
good IQ can cover many aspects of the validation process. C&M Scientific can offer advice on
the scope of such documentation. We have a small library of protocols available as examples.
Operational Qualification
Most companies should achieve this level of validation.
Operational Qualification
Most companies should achieve this level of validation. C&M Scientific have a considerable
experience in executing OQ. From the simple temperature control to complex analytical equipment,
establishing and executing high quality OQ is a strong element of C&M Scientific's
capability.
Performance Qualification
Perhaps the most meaninful element of validation.
Performance Qualification
Perhaps the most meaningful element of validation. Testing the equipment in a dynamic state with
the plan use of load configurations provides the most valued data in supporting a regulated
process. In conjunction with the client, C&M Scientific can construct high quality
documentation and the execution of PQ.
Additional C&M Scientific Ltd. Services
C&M Scientific Ltd can provide qualification protocols for all instruments to IQ and OQ level. For selected instruments (commonly multi-component systems) C&M
Scientific Ltd. can provide Performance Qualification protocols. Our team of validation support personnel can also assist in the preparation of PQ protocols.
Get in touch to enquire about how we can aid you in the validation of your laboratory processes and
its equipment.
Enquiry Form
The FDA GMP CFR 211
Laboratory controls shall include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to
appropriate standards of: identity, strength, quality and purity.
An extract from the FDA Compliance Program Guidance Manual says that: Laboratory equipment and procedures must be qualified and validated.
Within the validation programme lies the whole area of qualification testing which is carried out at predefined intervals and sets out to show that the equipment has
been installed and operates or performs to the manufacturer's requirements or specifications and is suitable for its intended use.
The following somewhat simplistic schematic of the qualification programme shows the relationship between the stages of qualification testing and validated use.
The first stage of the qualification testing is known as pre-purchase qualification, which is the user's formal functional qualification. Commonly called a User
Requirement Specification (URS), this document lays down the requirements for intended use including application and environmental requirements.