SUPERDEX 200 INCREASE 5/150 GL

Code: ge28-9909-45 N1-1

Superdex 200 Increase size exclusion chromatography columns are well suited for high-resolution analysis and small-scale purification of monoclonal antibodies (mAb) and other biomolecules with Mr~ ...


read more

Your Price
£2,370.00 EACH

Superdex 200 Increase size exclusion chromatography columns are well suited for high-resolution analysis and small-scale purification of monoclonal antibodies (mAb) and other biomolecules with Mr~ 10 000 to ~ 600 000.

  • Enhanced performance: improved resolution and runtime compared to predecessor Superdex 200
  • Very high resolution: small bead size and narrow particle size distribution provide high resolution, for high protein purity
  • High flow rates: rigid beads give excellent pressure/flow properties

Superdex 200 Increase is a next-generation, dextran-agarose composite matrix for SEC. With smaller and more rigid beads than their predecessors, Superdex Increase columns deliver higher resolution purification in shorter run times.

Superdex 200 Increase has a selectivity curve optimiSed for excellent resolution of antibodies and macromolecules within the range Mr ~ 100 000 to ~ 300 000. It is well suited for detection and separation of antibody monomers, dimers, and aggregates present in monoclonal antibody preparations.

The outstanding resolving power of this resin facilitates protein characteriSation, including analysis of antibody size variants, assessment of membrane protein size homogeneity, and the study of protein-protein interactions.

Superdex 200 Increase is optimiSed to give high resolution separation for proteins with molecular weights in the range Mr ~ 100 000 to ~ 300 000. Superose 6 Increase provides a complementary fractionation range, resolving very large protein complexes and macromolecules that Superdex 200 Increase cannot separate.

This agarose-based resin is alkali-resistant and supports cleaning-in-place (CIP) procedures. This capability allows the same column to be used for different proteins, with minimal risk of carry-over between samples.

Regular cleaning can also increase column lifetime.

cleaning1 - 14
materialpolyethylene filter
materialborosilicate glass column
particle size8.6 µm
parameter≤0.75 mL/min flow rate
parameter≤0.75 ml/min flow rate
parameter≤3.0 Mpa (725 psi)
matrix active groupphenyl phase
working range3 - 12
mfr. no.GE Healthcare, 28-9909-45
shelf lifePlease be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
sample volume4-50 mL
mol wt10000-600000 Da (globular proteins)
matrixagarose dextran composite
separation techniquesize exclusion (SEC)
availabilitynot available in North America
bed volume~3 mL
column L × I.D.15 cm × 5 mm
This product has met the following criteria: