CHEMOTAXIS ASSAY, 24-WELL 5 ?M, COLOR

Code: ecm506 D2-231

Not available outside of the UK & Ireland.

Application

The Millipore 5 µm QCM™ Chemotaxis Assay 24-well-colorimetric is performed in a Migration Chamber, based on the Boyden chamber principle. The 5 µm...


read more

Your Price
£555.00 EACH
£666.00 inc. VAT

Not available outside of the UK & Ireland.

Application

The Millipore 5 µm QCM™ Chemotaxis Assay 24-well-colorimetric is performed in a Migration Chamber, based on the Boyden chamber principle. The 5 µm pore size of this assay′s Boyden chambers is appropriate for studying a subset of fibroblast or cancer cell migration. The quantitative nature of this assay is useful for screening of pharmacological agents. Each kit provides sufficient materials for the evaluation of 24 samples.

The Millipore 5 µm QCM™ Chemotaxis Assay 24-well-colorimetric is intended for research use only; not for diagnostic applications.

Components

Sterile 5 µm 24-well Cell Migration Plate Assembly: (Part No. 2005708) Two 24-well plates with 12 inserts per plate (24 inserts total/kit).Cell Stain: (Part No. 90144) one 20 ml.Extraction buffer: (Part No. 90145) one 20ml.Cotton Swaps: (Part No. 10202) 50 each.Forceps: (Part No. 10203) One each.

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

General description

Also available: Cell Comb™ Scratch Assay! Get biochemical data from a scratch assay!Click Here

Introduction
Cell migration is a fundamental function of normal cellular processes, including embryonic development, angiogenesis, wound healing, immune response, and inflammation (1, 2). Most cells are sized from 30 to 50 µm can migrate through 3 to 10 µm pore. Microporous membrane inserts are widely used for cell migration and invasion assays. The most widely accepted of which is the Boyden Chamber assay. The Boyden Chamber system uses a hollow plastic chamber, sealed at one end with a porous membrane. This chamber is suspended over a larger well which may contain medium and/or chemoattractants. Cells are placed inside the Chamber and allowed to migrate through the pores, to the other side of the membrane. Migratory cells are then stained and counted. Most migration assays utilize an 8 µm pore size, as this is appropriate for most cell types, e.g. epithelial and fibroblast cells. The Millipore 5 µm QCM™ Chemotaxis Assay 24-well- colorimetric utilizes a 5 µm pore size, which is appropriate for a subset of fibroblast cells or cancer cells such as NIH-3T3 and MDA-MAB 231 cells. Cells migrated toward chemoattractants were measured by crystal violet, a nucleic dye, and quantified by spectrophotometers. The system may be adapted to study different types of cell migration, including haptotaxis, random migration, and chemokinesis.
The Millipore QCM™ 5 µm Chemotaxis Assay 24-well-colorimetric provides a quick and efficient system for quantitative determination of various factors on cell migration, including screening of pharmacological agents, evaluation of integrins or other adhesion receptors responsible for cell migration, or analysis of gene function in transfected cells.
In addition, Chemicon continues to provide numerous migration, invasion, and adhesion products including:
QCM™ 8µm 24-well Chemotaxis Cell Migration Assays (ECM508, 509)
QCM™ 5µm 24-well Chemotaxis Cell Migration Assay- Fluorometric (ECM507)
QCM™ 8µm 96-well Chemotaxis Cell Migration Assay (ECM510)
QCM™ 5µm 96-well Chemotaxis Cell Migration Assay (ECM512)
QCM™ 3µm 96-well Chemotaxis Cell Migration Assay (ECM515)
QCM™ 96-well ECMatrix™ Cell Invasion Assay (ECM555)
QCM™ 96-well Collagen-based Cell Invasion Assay (ECM556)

Legal Information

Accutase is a registered trademark of Innovative Cell Technologies, Inc.

CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany

Packaging

24 wells

1 plate in 24 wells

Storage and Stability

The 5 µm 24-well Cell Migration Plate and forceps are stored at room temperature. Cell stain and extraction buffer can be store at 2° to 8°C up to the expiration date. Do not freeze any components.

detection methodcolorimetric
manufacturer/tradenameQCM, Chemicon®
Quality Level100
shipped inwet ice
species reactivity (predicted by homology)all
technique(s)cell based assay: suitable, activity assay: suitable
This product has met the following criteria: