SupelMIP SPE - TSNAs, bed wt. 50 mg, volume 10 mL , (LRC), pk of 50

Code: 53221-u D2-231

Not available outside of the UK & Ireland.

Application

Developed for the selective extraction of tobacco specific nitrosamines (NNN, NNK, NAT, and NAB) from human urine. The method is highly reproducible and ...


read more

Your Price
$700.35 EACH
$840.42 inc. VAT

Not available outside of the UK & Ireland.

Application

Developed for the selective extraction of tobacco specific nitrosamines (NNN, NNK, NAT, and NAB) from human urine. The method is highly reproducible and offers an average recovery of 80% (95% for NNK and NAT; and 70% for NNN and NAB). Detection limits of 4 pg/mL are readily achieved for urine samples using LC-MS-MS analysis.

Features and Benefits

Highly selective SPE for trace analysis in complex matrices Achieve lower detection limits Significant time and cost savings Improved MS-compatibility

General description

SupelMIP SPE phases were developed by MIP Technologies AB, which is one of the leading authorities and commercial pioneers of molecular imprinted polymers for process scale separations, analytical chromatography, and sample preparation. The SupelMIP SPE line consist s of highly cross-linked polymers that are engineered to extract a single analyte of interest or a class of structurally related analytes with an extremely high degree of selectivity. This is possible because selectivity is introduced during MIP synthesis in which a template molecule, designed to mimic the analyte, guides the formation of specific cavities or imprints that are sterically and chemically complementary to the analyte(s) of interest.By careful design of the imprinting site, either by molecular modeling, experimental design, or screening methods, the binding cavities can be engineered to offer multiple interaction points with the analyte(s) of interest. This leads to a stronger interaction between the solid-phase and the analyte(s). As a consequence, harsher wash conditions can be tolerated during SPE methodology resulting in cleaner extracts. Because extraction selectivity is significantly improved, lower background is observed allowing analysts to achieve lower limits of detection. Visit www.sigma-aldrich.com/supelmip to learn more.

Legal Information

SupelMIP is a registered trademark of Sigma-Aldrich Co. LLC

compositionbed wt., 50 mg
materialpolypropylene tube
packagingpk of 50
product lineSupelMIP®
Quality Level100
technique(s)solid phase extraction (SPE): suitable
volume10 mL , LRC
This product has met the following criteria: